Five Problems Leading To Low Purity Of Nitrogen Generator

Five Problems Leading

1. The oxygen probe of online detection nitrogen analyzer is aging, so that the detection data is incorrect.

2. The main problem of insufficient nitrogen purity comes from the nitrogen generator itself, which means there are many faults in the nitrogen generator system itself.

3. Adsorption pressure problem. The better adsorption pressure of CMS is more than 0.65 ~ 0.85 MPa. If it is lower, it cannot produce nitrogen normally. Insufficient air supply of compressor and air leakage of pneumatic valve are the two main reasons.

4. The gas flow exceeds the design capacity of the nitrogen generator

5. Due to the poisoning of CMS in nitrogen generator, the adsorption capacity of CMS decreases.